网站首页期刊介绍通知公告编 委 会投稿须知电子期刊广告合作联系我们
最新消息:
MRI与肾功能
作者:王喆妍1 骆璇2 王东进3 
单位:1.南京大学医学院附属南京市鼓楼医院,麻醉科,江苏,南京,210008;南京大学医学院附属南京市鼓楼医院,心胸外科,江苏,南京,210008; 2.南京大学医学院附属南京市鼓楼医院,麻醉科,江苏,南京,210008; 3.南京大学医学院附属南京市鼓楼医院,心胸外科,江苏,南京,210008
关键词:核磁共振 肾功能  综述[文献类型] 
分类号:R445.2, R692.044.52
出版年·卷·期(页码):2005·24·第四期(273-275)
摘要:

临床上检测肾功能的方法有很多,但这些方法各有不足之处.理论上MRI在检测肾功能方面有明显的优势,但尚未得到临床应用.作者就MRI检测肾功能的优势、可行性、方法及其应用情况进行了综述.

The clinical methods being used to depict renal function have their disadvantages respectively. Many experiments have showed that MRI has the potential advantages on showing renal function, but it has not been used clinically. This paper has reviewed the advantages, possibility, technologic method and applications of using MRI to show renal function.

参考文献:

[1] Huang A J, LEE V S, RUSINEK H. MR imaging of renal function. 2003(1). doi:10.1016/S0033-8389(3)00066-6
[2] Lee V S, RUSINEK H, NOZ M E. Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience. 2003(1). doi:10.1148/radiol.2271020383
[3] Lemaitre L, CLAUDON M, FAUQUET I. Imaging of chronic and intermittent adult upper urinary tract obstruction. 2004(2). doi:10.1016/S0221-0363(4)97570-1
[4] Choyke P L, AUSTIN H A, FRANK J A. Hydrated clearance of gadolinium-DTPA as a measurement of glomemlar filtration rate. 1992. doi:10.1038/ki.1992.230
[5] DUMOULIN C L, BUONOCORE M H, OPSAHL L R. Noninvasive measurement of renal hemodynamic function using gadolinium enhanced dynamic magnetic resonance imaging. 1994. doi:10.1002/mrm.1910320312
[6] NIENDORF E R, GRIST T M, LEE JR FT. Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging. 1998
[7] COULAM C H, LEE J H, WEDDING K L. Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal arterial stenosis. 2002(1). doi:10.1148/radiol.2231010420
[8] WEN J G, CHEN Y, RINGGAARD S. Evaluation of renal function in normal and hydronephrotic kidneys in rats using gadolinium diethylenetetramine pentaacetic acid enhanced dynamic magnetic resonance imaging. 2000(2). doi:10.1016/S0022-5347(5)67758-0
[9] ROHRSCHNEIDER W K, BECKER K, HOFFEND J. Combined static - dynamic MR urography for the simultaneous evaluation of morphology and function in urinary tract obstruction: findings in experimentally induced ureteric stenosis. 2000(8). doi:10.1007/s002470000273
[10] Fukuda Y, WATANABE H, TOMITA T. Evaluation of glomerular function in individual kidneys using dynamic magnetic resonance imaging. 1996(1). doi:10.1007/BF01395707
[11] KATZBERG R W, BUONOCORE M H, IVANOVIC M. Functional,dynamic,and anatomic MR urography:feasibility and preliminary findings. 2001(2). doi:10.1016/S1076-6332(3)80720-1
[12] SZOLAR D H, PREIDLER K, EBNER F. Functional magnetic resonance imaging of human renal allografts during the posttransplant period:preliminary observations. 1997(1). doi:10.1016/S0730-725X(97)00088-X
[13] AGILDERE A M, TARHAN N C, BOZDAGI G. Correlation of quantitative dynamic magnetic resonance imaging findings with pathology results in renal transplants:a preliminary report. 1999. doi:10.1016/S0041-1345(99)00808-8 

服务与反馈:
文章下载】【发表评论】【查看评论】【加入收藏
提示:您还未登录,请登录!点此登录
您是第 416883 位访问者


copyright ©《东南大学学报(医学版)》编辑部
联系电话:025-83272481 83272483